Skip to content Skip to navigation

PHOENIX Quadro EU

Part Number: 250000V02

PHOENIX

The new generation of leak detectors. Where precision meets speed, with your convenience in mind.

Often the success of any business depends on quality, and having the right tools and equipment is critical to ensuring top performance and output across R&D departments, as well as in fast-paced production and manufacturing facilities. We also see applications becoming more specialized, processes being more demanding, yet time for analysis and testing becoming less. However, when it comes to vacuum system leak detection you can rely on Leybold and the newest generation of PHOENIX leak detectors, where precision meets speed, with your convenience in mind.

 

A new degree of precision - Whether you are in a research lab, or production of high-class goods, quality depends on how accurately you detect deviations. Now, help is at hand: the new PHOENIX generation delivers the highest helium sensitivity for unbeatable reliability and stability.

 

A new level of speed - If you are looking to accelerate the leak test of your system or speed up quality control in manufacturing, time is of the essence. The new PHOENIX leak detectors feature an improved measurement system with faster response times than ever before.

 

A new dimension of comfort and choice - The new PHOENIX offers a choice of three models, so you are sure to find the right leak detector for your needs, with simple operation, integrated touchscreen and Wi-Fi options. New software functions let you add an external display to monitor and run measurements from anywhere for added flexibility. And thanks to internal and external data logging, no measured value is ever lost.

Features and Benefits

  • Highest accuracy and reliability thanks to proven measurement system
  • Fastest helium pumping speed allows most efficient measurements
  • Consistency and convenience: Save all parameters and copy them to other PHOENIX leak detectors
  • Innovative touchscreen with intuitive menu structure
  • Handy and portable: very small dimensions and low weight
  • Log in using Wi-Fi on your smart phone or tablet. No app or software needed!
  • Easy internal and external data logging: no measured values are ever lost
  • HDMI interface lets you check leaks from anywhere by adding external displays
  • Find the perfect fit: three different models to better suit your needs

General Product Information

Connection Power IEC EN60320 C14 - Male (for C13 plug on mains cable)
Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Cooling Method Air Cooling (forced - fan)
Dimension Height 0.475
Dimension Length 0.495
Dimension Width 0.318
IP Rating IP30
Supply Voltage 1Ph 220-240V 50/60Hz
Weight 41.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
ProductCertification CE
connectionPurgeGasBallastVentConnector Hose OD 8 mm

Classification

Principle Of Measurement Helium leak detector - sector field mass spectrometer
High / Medium / Rough Vacuum Classification High Vacuum Pump

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 60.00
Temperature Ambient Operation Min 10.00
Temperature Ambient Storage Min 10.00

Connectivity - Communication Interface

Communication Interfaces Customer 7" touch screen
Connection Accessories Connector PHOENIX Remote1
PHOENIX Remote2
PHOENIX Accessory Port Sniffer
PHOENIX HDMI
PHOENIX USB
PHOENIX LD - IO Interface

Performance Data

Pumping Speed Air Nitrogen (@50Hz or max @default setting) 3.000 × 10⁻³
Pumping Speed Helium in Fine Mode 1.200 × 10⁻³
Ramp Up Time 110.00
Performance Comment The lowest detectable leak rate is given for Vacuum Operation / Sniffer Operation. These performances are specific to a defined gas. Pumping speeds for nitrogen represent the maximum roughing pumping speed of the backing pump.
Lowest Detectable Leak Rate for Helium 5.000 × 10⁻¹³
5.000 × 10⁻¹³
Lowest Detectable Leak Rate for Hydrogen 1.000 × 10⁻⁹
1.000 × 10⁻⁹
Pumping Speed Helium in Gross Mode 4.000 × 10⁻⁴
Pumping Speed Helium in Ultra Mode 3.100 × 10⁻³
DetectableMasses 2 amu
3 amu
4 amu