Skip to content Skip to navigation

Specifications

Connection Vacuum Inlet Flange DN 40 ISO-KF (NW40)
Connection vacuum outlet flange DN 16 ISO-KF (NW16)
Cooling Method Air Cooling (convection) Air Cooling (forced - fan) Water Cooling
Supply Voltage DC 24V DC 48V
Power Total Rated 240.00
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.038
Pressure Ultimate 8.000 × 10⁻⁶

TURBOVAC 90 i - DN 40 KF

Part Number: 810011V1000

Variant

Explore the range of variants given below to compare the product

Short Description Part Number variantTmpPerformanceModel
810011V1000 TURBOVAC i - frontend 1 (basic)
810011V2000 TURBOVAC i - frontend 2 (Anybus/Fieldbus extention)
810011V3300 TURBOVAC iX - Xtention box controller
810031V1000 TURBOVAC i - frontend 1 (basic)
810031V2000 TURBOVAC i - frontend 2 (Anybus/Fieldbus extention)
810031V3300 TURBOVAC iX - Xtention box controller
810041V1000 TURBOVAC i - frontend 1 (basic)
810041V2000 TURBOVAC i - frontend 2 (Anybus/Fieldbus extention)
810041V3000 TURBOVAC iX - Xtention box controller
810041V3300 TURBOVAC iX - Xtention box controller

TURBOVAC i/iX

TURBOVAC i is a well-proven turbomolecular pump platform ranging from 90 to 1450 l/s. TURBOVAC i comes with the latest hybrid bearing design offering a permanent magnet upper bearing paired with an oil-free lower mechanical bearing offering the cleanest high vacuum conditions.

 

With TURBOVAC i we offer variants covering UHV (Ultra High Vacuum), throughput IND (Industrial) as well as iR (radiation robust) variants with remote electronics. TURBOVAC i pumps are available with a compact interface offering the control of up to two accessories, basic RS485, USB and DIGITAL I/O control. The TURBOVAC i series also offers the full spectrum of field bus support. The universal connection called "Anybus" enables communication via Profibus, Ethernet IP, ProfiNET as well as EtherCAT through selectable modules.

 

TURBOVAC iX also offers the Anybus interface, the ability to control your fore vacuum pump, and up to 6 accessories, a gauge interface turning the pump into a full vacuum control solution. Along with single inlet pumps, we offer a wealth of multi-inlet, cartridge pumps, and customized products via our Customer Focused Engineering team - please come and talk to our sales teams.

 

TURBOVAC i pumps, in general, come stand-alone - the suitable power supply unit, comms/power cables, and cooling options need to be ordered separately. TURBOVAC 1350, 1450 and the 850, 950 IND variants always come already equipped with a water cooling block.

TURBOVAC 90 i - DN 40 KF

It can be operated in any orientation. This product comes without any additional cooling device - an air cooler or a water cooling block need to be ordered separately. As an electronic interface this product comes with the basic compact interface.

Features and Benefits

  • Superior performance - high pumping speed for light gases combined with high compression
  • Stress-free operation
  • High flexibility in our platform for standard and especially in customized products
  • Higher resistance to particles
  • Smart interfaces and intuitive software platform with LeyAssist
  • Operation in any orientation

General Product Information

Accessories / Scope of Supply TURBOVAC i pumps come stand-alone - the suitable power supply unit, comms/power cables, and cooling options need to be ordered separately. IND industrial variants come with an equipped water cooling unit and are water cooling only.
Connection Cooling 6x1 mm flexible hose quick connection
Connection vacuum outlet flange DN 16 ISO-KF (NW16)
Connection Vacuum Inlet Flange DN 40 ISO-KF (NW40)
Cooling Method Air Cooling (convection)
Air Cooling (forced - fan)
Water Cooling
Dimension Height 0.202
Dimension Length 0.105
Dimension Width 0.105
IP Rating IP40
Supply Frequency DC Voltage
Supply Voltage DC 24V
DC 48V
Weight 2.90
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 40 ISO-KF (NW40) | DN 16 ISO-KF (NW16)
ProductCertification CE
UL
CSA
connectionPurgeGasBallastVentConnector 1/8" BSPP (or G 1/8") Female
1/8" BSPP (or G 1/8") Female

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Storage Max 70.00
Temperature Ambient Operation Min 5.00
Temperature Ambient Storage Min -15.00
Magnetic Field Resistance Max (covering worst direction - come and consult us for more details) 5.500 × 10⁻³ T

Classification

Dry or Wet Pump Dry
Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
High / Medium / Rough Vacuum Classification High Vacuum Pump
Vacuum Pump Technology Turbomolecular Pump - hybrid bearing oil free

Performance Data

Compression Ratio Air Nitrogen 1.000 × 10¹¹
Compression Ratio Helium 1.000 × 10⁸
Compression Ratio Hydrogen 5.000 × 10⁷
Power Consumption Max 240.00
Power Total Rated 240.00
Pressure Ultimate 8.000 × 10⁻⁶
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.038
Pumping Speed Argon 0.036
Pumping Speed Helium 0.039
Pumping Speed Hydrogen 0.031
Ramp Up Time 90.00
Nominal rotational speed 1200.00
Performance Comment The compression of a TMP is a value describing how good the design can compress a gas type at special conditions. Compression data is measured only using the CF flange variants. The values are stated for all family members. For some pump classes we are stating different pumping speeds ISO > CF flange as small differences in geometry influence their performance leading to a difference >5%.
Pressure Backing Max 1400.00
Compression Ratio Argon 1.000 × 10¹¹

Connectivity - Communication Interface

Communication Interface Protocol USS Universal Serial Interface Protocol
Communication Interfaces Customer RS485 (serial)
REMOTE X1 (Parallel I/O)
USB
Connection electrical comms interface connector DSUB 9-PIN - Male
DSUB HD 15-PIN - Female (high density)
USB type B - Female

Variants

Installation Any orientation
variantTmpPerformanceModel TURBOVAC i - frontend 1 (basic)

Operation Conditions - Limitations

Flow Cooling Water Min 8.333 × 10⁻⁶
Temperature Cooling Water Max 35.00
Temperature Cooling Water Min 15.00
Flow Cooling Water Max 1.667 × 10⁻⁵
Pressure Permissible Cooling Water - Min and Max 4.000 × 10⁵
4.000 × 10⁵
Flow Purge Gas Ballast 0.043
Product Title Part Number Price Add to cart
Mounting Kit - Turbo.Power Intergra to TURBOVAC 90 250 i 800100V0005 -
Air Cooling Unit - TURBOVAC 90i radial 800136V0007 -
Start-stop switch for TURBOVAC i/iX 800110V0021 -
Cable Power DC - TURBOVACi TURBO.POWER integra 3m 24V DC 800096V0300 -
Vent valve - 24V DC - 1/8" BSPP (G) Male (450mm) 800120V0012 -
Cable Power DC - TURBOVACi TURBO.POWER integra 1m 24V DC 800096V0100 -
Air Gas Filter - TURBOVAC 1/8" BSPP (G) Male 800110V0022 -
Plug DC - 24/48 V DC TURBOVAC i/iX (90/250/350/450) 800090V0000 -
Communication cable - USB cable 2.0 type A/B 1.8m 800110V0108 -
TURBO.CONTROL i 800100V0004 -
Water Cooling Unit - TURBOVAC i 1/8" BSPP (G) -- tube - (90/250/350/450) 800135V0005 -
Purge Valve - EM 24V DC - 1/8" BSPP (G) Male (450mm) 800120V0013 -
Centring Ring - Al FKM O-Ring DN 40 ISO-KF 18208 -
Centring Ring - St St FKM O-Ring DN 40 ISO-KF 88348 -
Clamping Ring - (ADC 12) AL DN 32/40 ISO-KF 18343 -
Cable Accessory - TURBOVAC i / TURBOLAB M8-M8 2m 800110V0016 -
Clamp - double claw for ISO-K Galvanised Steel pk4 DN 63 - 250 ISO-K (25-35mm) 26702 -
Connector Accessory Y-connector - TURBOVAC i / TURBOLAB M8 800110V0020 -
Power Failure Vent Valve - 24V DC - 1/8" BSPP (G) Male (450mm) 800120V0022 -
Water Cooling Unit - TURBOVAC i 1/4" BSPP (G) -- tube - (90/250/350/450) 800135V0006 -
Clamp - double claw for ISO-K St St pk4 DN 63 - 250 ISO-K (19-27mm) 88799 -
Air Cooling Unit - TURBOVAC 90 - 250i axial 800136V0008 -
Clamp - double claw for ISO-K Galvanised Steel pk4 DN 63 - 250 ISO-K (19-27mm) 26701 -
Cable Accessory - TURBOVAC i / TURBOLAB M8-M8 5m 800103V0003 -
Center ring with splinter guard - DN 40 ISO-KF fine 800133V0002 -
Cable Power DC - TURBOVACi TURBO.POWER integra 5m 24V DC 800096V0500 -
THERMOVAC TTR 91 RN - DN 16 ISO-KF 21L1011100 -
PENNINGVAC PTR 90 RN - DN 40 CF 23L0041100 -