Especificaciones

Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Connection vacuum outlet flange DN 25 ISO-KF (NW25)
Supply Voltage 3F 219-242V/ 380-420V 50Hz
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 7.139 × 10⁻³
Presión final 0.200

TRIVAC D 25 B - ATEX 3Ph Category: 3i + 3o

Numero de parte: 140170

Oil Rotary Vane Pumps Two-Stage

Leybold TRIVAC & NEO D oil sealed double stage vane pumps are well known and being used in all areas of vacuum engineering and are equally suited for both industrial production and research applications. The TRIVAC & NEO D pumps, used to generate a rough and medium vacuum or as backing pumps in pump combinations with Roots vacuum pumps or high vacuum pumps, have the ability of pumping down from the atmosphere.

TRIVAC B and BCS

The TRIVAC B pump excels with a high vacuum performance by delivering a low ultimate pressure and high water vapor tolerance with an integrated gas ballast. With a low noise level and low vibration, TRIVAC B pumps do not add to the noise in your working environment. The well-proven robust design with low thermal losses and air-cooled design makes the TRIVAC B pumps portable and compact. A comprehensive range of accessories and variants are available to offer a complete solution to meet the requirements of your applications

TRIVAC D 25 B HazLoc

TRIVAC D 25 B ATEX is a recognized top notch product with an excellent quality & reliability track record

Features and Benefits

  • Process control: Unmatched ultimate pressure
  • Peace of use: Integrated gas ballast for High water vapor tolerance
  • Process safety: Low oil back streaming thanks to Anti-suckback valve controlled via the oil pressure
  • Up-time & reliability: Built-in oil gear pump for lubrication
  • Process control: ATEX Cat 3 inside and outside

General Product Information

Connection vacuum outlet flange DN 25 ISO-KF (NW25)
Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Dimensión de altura 0.263
Longitud de cota 0.572
Dimensión de anchura 0.185
IP Rating IP55
Supply Frequency 50 Hz
Power Supply Phase 3-Ph
Supply Voltage 3F 219-242V/ 380-420V 50Hz
Peso 32.00
Comentarios de Dimensión The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Conexión Brida de Entrada / Salida DN 25 ISO-KF (NW25) | DN 25 ISO-KF (NW25)

Performance Data

Power Total Rated @50Hz 750.00
Presión final 0.200
Pressure Water Vapour Max 2500.00
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 7.139 × 10⁻³
Velocidad de bombeo, aire y nitrógeno 50 Hz 7.139 × 10⁻³
Velocidad de bombeo, aire y nitrógeno 60 Hz 8.556 × 10⁻³
Nominal Rotational Speed 50Hz 25.00
Nominal Rotational Speed 60Hz 30.00

Environmental Conditions

Temperatura ambiente de funcionamiento máx. 40.00
Temperature Ambient Operation Min 5.00

Operation Conditions - Limitations

Altitud máxima 1000.00

Classification

Dry or Wet Pump Wet
Product Pressure Range Medium Vacuum: 1 mbar - 1·10⁻³ mbar
High / Medium / Rough Vacuum Classification Rough Vacuum Pump
Vacuum Pump Technology Oil Rotary Vane Pump Two-Stage