Sensor PENNINGVAC PR 27 - DN 40 CF
Variantes disponibles
Consulte las siguientes opciones para comparar las distintas variantes del producto.
| DESCRIPCION | N.º de catálogo |
|---|---|
| 13646 | |
| 13647 | |
| 15752 |
Medidor Pasivo
Unlike active gauges, in passive gauges only the sensor is included, while the electronics are excluded. Passive measurement devices completely separate the measurement part from the driver electronics. The head attached to the system contains only the parts needed for the physical measurement and all other electronics are contained in the control unit. Usually, the control units are also fitted with analog voltage outputs, switch-point relay contacts and digital interfaces.
Passive gauges offer direct measurement of the sensor signal and the cable has an influence on the measuring signal. They require particular cables according to indicator type.
The controller is also the measuring device, so that the power supply only comes from the controller. In a similar fashion, the display is located uniquely on the controller.
Passive gauges are tolerant of radiation and high bakeout temperatures are possible, in contrast to active gauges.
THERMOVAC TR Series (Pirani / Thermal Conductivity): Meant for rough to medium vacuum levels (1000 mbar down to approx. 5 × 10⁻⁴ mbar). Common variants include the TR 211, TR 212, and TR 216.
PENNINGVAC PR Series (Cold Cathode / Ionization): Tailored for the high-vacuum region, tracking pressures into lower ranges without a hot filament. Key models include the PR 25, PR 26, PR 27, and PR 28.
IONIVAC IE Series (Hot Cathode / Bayard-Alpert): Explicitly optimized for ultra-high vacuum (UHV) applications, capable of measuring down to 1 × 10⁻¹² mbar. Key models include the IE 414 and IE 514 (Extractor gauge).
COMBIVAC CM: A controller for up to two passive Pirani gauges and one passive cathode gauge Vacuum gauges and pump controllers - Leybold Global.
IONIVAC IM: Tailored specifically for two passive hot cathode gauges to monitor UHV pressures Vacuum gauges and pump controllers - Leybold Global.
Features and Benefits
- Measurement from atmosphere to 10E-12 mbar - Gauge contains only sensor – measurement signal is processed by separate controller
- Advantage: Sensor is less sensitive to radiation and more bakeable
- Measurement cables up to 100m
- Automatic switching from THERMOVAC to Penning & UHV sensors
Información general sobre el producto
| Power Supply Frequency | Tensión CC |
| Comentarios de Dimensión | Las dimensiones de longitud, ancho y altura intentan describir la forma exterior de este producto en su orientación típica cuando está sobre el suelo. Siempre recomendamos verificar las dimensiones detalladas proporcionadas en los dibujos 2D del manual de instrucciones o las formas 3D proporcionadas en los modelos 3D. |
Clasificación
| Principio de clasificación de la medición | Medidor de vacío pasivo de cátodo frío (Penning) |
| Titulo del producto | Designación | Precio | Añadir a la cesta |
|---|---|---|---|
| Calibre del cable - Sensor PR - 5m | 16288 | - | |
| Calibre del cable - sensor PR - 15m | 12449 | - | |
| Calibre de cable - sensor PR - 10m | 16289 | - | |
| Calibre de cable - sensor PR - 30m | 12450 | - | |
| Calibre de cable - sensor PR - 75m | 12453 | - | |
| Calibre de cable - Sensor PR - 50m | 12452 | - | |
| Calibre del cable - sensor PR - 20m | 15756 | - | |
| Calibre de cable - Sensor PR - 100m | 12454 | - |
| Titulo del producto | Designación | Precio | Añadir a la cesta |
|---|---|---|---|
| COMBIVAC CM51 - RS232/485 | 230110 | - | |
| COMBIVAC CM51 - Profibus | 230111 | - | |
| COMBIVAC CM52 - con RS232 / 485 | 230115 | - | |
| COMBIVAC CM52 - con PB / RS232 / RS485 | 230116 | - |