Short Description Part Number Connection Vacuum Inlet Flange Dimension Length Weight
22L0021100 DN 25 ISO-KF (NW25) 0.092 0.350
22L0041100 DN 40 ISO-F 0.098 0.630

PENNINGVAC PTR

PENNINGVAC PTR - Leybold Vacuum is proud to introduce its latest update of the cold-cathode gauge technology. With the PTR 90 RN wide range and PTR 225 RN pure cold cathode you get the latest technology fitting within the same family characteristics as our latest pirani gauge TTR 91 RN.

Features and Benefits

  • Easy monitoring and control
  • Robust
  • Flexibility
  • Easy serviceability
  • In-house manufacturing from the expert
  • 2 interfaces to choose from
  • Reduced footprint
  • Compatibility
  • Adaptive led pressure indication
  • Wide range power supply

General Product Information

Connection Vacuum Inlet Flange DN 25 ISO-KF (NW25)
Dimension Height 0.045
Dimension Length 0.092
Dimension Width 0.045
IP Rating IP40
Supply Frequency DC Voltage
Supply Voltage DC 15-48V
Weight 0.350
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.

Classification

Product Pressure Range High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar
Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Principle Of Measurement Cold-cathode vacuum gauge (IM inverted magnetron)

Performance Data

Measurement Uncertainty 1x10-2 to 1x10-8 mbar ±30%
Power consumption Max String 4W
Pressure Measurement Min 1.000 × 10⁻⁷
Pressure Measurement Max 1.00

Environmental Conditions

Temperature Ambient Operation Max 50.00
Temperature Ambient Storage Max 70.00
Temperature Ambient Operation Min 0.000
Temperature Ambient Storage Min -30.00

Material of Construction

Material Body Stainless Steel 1.4404 / 316 L / X2 CrNiMo 17 13 2
Material Exposed to Vacuum Stainless Steel 316L and 304L, Glass, Molybdenum, Trace of Nickel and Nickel iron

Connectivity - Communication Interface

Communication Interface Protocol 0.667 - 10 V log linear with pressure PTR 225 RN
Communication Interfaces Customer 0-10 V (analog output - linear)
Connection electrical comms interface connector RJ45 (FCC 68) - Female
Status Indicator LED Light Ring

Operation Conditions - Limitations

Pressure Absolute Inlet Continous Max 1.500 × 10⁵
Pressure Inlet Max Overpressure 1.000 × 10⁶
Temperature Baking Max (Elec. Removed) 150.00
Temperature Baking Max 50.00

Variants

Variant Gauges PTR 225 RN (linear 0-10V output)