Skip to content Skip to navigation

Specifications

Connection Vacuum Inlet Flange DN 100 ISO-K
Connection vacuum outlet flange DN 63 ISO-K
Cooling Method Water Cooling
Supply Voltage 3Ph 380-480V 50/60Hz
Power Total Rated 19600.00
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.222
Pressure Ultimate 0.500

DRYVAC DV 800 - with Energy Saver

Part Number: 112080V16-1

Variant

Explore the range of variants given below to compare the product

DRYVAC

The benchmark for industrial applications! Meet the models in our smart DRYVAC series. The DRYVAC family offers product in a pumping speed range from 200 to 1600 m3/h. By combining these screw pumps with our RUVAC roots pump portfolio all pumping speed requirements can be met. Enjoy best-in-class performance, reliability and efficiency.

 

What makes top-performing pumps even more intelligent? Smart accessories. All DRYVAC models are equipped with a frequency converter and offer compatibility with a intelligent range of fieldbus protocols for maximum flexibility. This built-in frequency converter operates in conjunction with three standard sensors to monitor all electrical, thermal and mechanical components. The sensors detect the exhaust pressure, motor temperature and water outlet temperature and issue status updates and warnings when needed. Taking efficiency up a notch: with a frequency converter, DRYVAC moves up a whole class, making it the most efficient pump available. Fieldbus compatibility makes DRYVAC vacuum pumps ready for the demands of smart manufacturing. All pumps offer serial I/O solutions including a RS485 interface and support for various fieldbus protocols.

Features and Benefits

  • Harshest applications ready - Hermetically sealed, several purge options, flushable
  • Plug & Play - Inbuilt intelligent FC, easy networking & control, IoT ready
  • Performance Driven - High and stable pumping speed
  • Energy Efficiency - Low power due to rotor design and blow off valves
  • Compact - Significantly smaller than all equivalent pumps

General Product Information

Connection vacuum outlet flange DN 63 ISO-K
Connection Vacuum Inlet Flange DN 100 ISO-K
Cooling Method Water Cooling
Dimension Height 0.420
Dimension Length 1.28
Dimension Width 0.570
IP Rating IP54
Supply Frequency 50 Hz
60 Hz
Power Supply Phase 3-Ph
Supply Voltage 3Ph 380-480V 50/60Hz
Weight 590.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 100 ISO-K | DN 63 ISO-K

Performance Data

Capacity Water Vapour 8.333 × 10⁻³
Power at Ultimate 7500.00
Power Total Rated 19600.00
Pressure Ultimate 0.500
Pumping Speed Air Nitrogen (@50Hz or max @default setting) 0.222

Environmental Conditions

Temperature Ambient Operation Max 45.00
Temperature Ambient Storage Max 60.00
Temperature Ambient Operation Min 5.00
Temperature Ambient Storage Min -20.00

Classification

Dry or Wet Pump Dry
Product Pressure Range Medium Vacuum: 1 mbar - 1·10⁻³ mbar
High / Medium / Rough Vacuum Classification Medium Vacuum Pump
Rough Vacuum Pump